{"product_id":"discover-energy-lynk-ii-communication-gateway","title":"Discover Energy Lynk II Communication Gateway","description":"\u003ch2 data-end=\"252\" data-start=\"195\"\u003eDiscover Energy Lynk II Communication Gateway\u003c\/h2\u003e\n\u003cp data-end=\"574\" data-start=\"254\"\u003eThe Discover Energy LYNK II Communication Gateway enables seamless communication between Discover lithium batteries and compatible inverters. Designed for solar and energy storage systems, it allows advanced monitoring, configuration, and closed-loop integration for optimized battery performance and system reliability.\u003c\/p\u003e\n\u003chr data-end=\"579\" data-start=\"576\"\u003e\n\u003ch2 data-end=\"638\" data-start=\"581\"\u003eDiscover Energy Lynk II Communication Gateway Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eClosed-Loop Integration \u003c\/strong\u003e– Enables real-time communication between Discover batteries and supported inverters for optimized charging and performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Battery Management Interface \u003c\/strong\u003e– Provides advanced configuration and system-level battery control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndoor Compact Design \u003c\/strong\u003e– Lightweight enclosure with built-in surface mount bracket for easy installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWide Operating Range\u003c\/strong\u003e – Reliable operation from -4°F to 122°F (-20°C to 50°C).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLow Power Consumption\u003c\/strong\u003e – Designed for efficient, continuous operation within energy storage systems.\u003c\/p\u003e\n\u003chr data-end=\"1203\" data-start=\"1200\"\u003e\n\u003ch2 data-end=\"1266\" data-start=\"1205\"\u003eDiscover Energy Lynk II Communication Gateway Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-end=\"1383\" data-start=\"1268\"\u003e\n\u003cstrong data-end=\"1300\" data-start=\"1268\"\u003eSolar Energy Storage Systems\u003c\/strong\u003e – Enables inverter-battery communication in residential and commercial ESS setups.\u003c\/li\u003e\n\u003cli data-end=\"1480\" data-start=\"1385\"\u003e\n\u003cstrong data-end=\"1416\" data-start=\"1385\"\u003eHybrid Inverter Integration\u003c\/strong\u003e – Supports closed-loop control with compatible inverter brands.\u003c\/li\u003e\n\u003cli data-end=\"1572\" data-start=\"1482\"\u003e\n\u003cstrong data-end=\"1502\" data-start=\"1482\"\u003eOff-Grid Systems\u003c\/strong\u003e – Optimizes battery charging and performance in remote installations.\u003c\/li\u003e\n\u003cli data-end=\"1682\" data-start=\"1574\"\u003e\n\u003cstrong data-end=\"1606\" data-start=\"1574\"\u003eBattery Monitoring Solutions\u003c\/strong\u003e – Provides centralized communication for system diagnostics and management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1687\" data-start=\"1684\"\u003e\n\u003ch2 data-end=\"1708\" data-start=\"1689\"\u003eWhat’s Included?\u003c\/h2\u003e\n\u003cul data-end=\"1782\" data-start=\"1710\"\u003e\n\u003cli data-end=\"1747\" data-start=\"1710\"\u003e\n\u003cp data-end=\"1747\" data-start=\"1712\"\u003e1 × LYNK II Communication Gateway\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1782\" data-start=\"1748\"\u003e\n\u003cp data-end=\"1782\" data-start=\"1750\"\u003e1 x USB cable (1 m, 3.28 ft) with a Type-B mini plug\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1782\" data-start=\"1748\"\u003e1 x User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1891\" data-start=\"1888\"\u003e\n\u003ch2 data-end=\"1956\" data-start=\"1893\"\u003eDiscover Energy Lynk II Communication Gateway Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2547\" data-start=\"1958\"\u003e\n\u003cthead data-end=\"1993\" data-start=\"1958\"\u003e\n\u003ctr data-end=\"1993\" data-start=\"1958\"\u003e\n\u003cth class=\"\" data-col-size=\"sm\" data-end=\"1978\" data-start=\"1958\"\u003e\u003cstrong data-end=\"1977\" data-start=\"1960\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"\" data-col-size=\"sm\" data-end=\"1993\" data-start=\"1978\"\u003e\u003cstrong data-end=\"1991\" data-start=\"1980\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2547\" data-start=\"2030\"\u003e\n\u003ctr data-end=\"2076\" data-start=\"2030\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2043\" data-start=\"2030\"\u003e\u003cstrong data-end=\"2042\" data-start=\"2032\"\u003eDevice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2076\" data-start=\"2043\"\u003eLYNK II Communication Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2107\" data-start=\"2077\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2095\" data-start=\"2077\"\u003e\u003cstrong data-end=\"2094\" data-start=\"2079\"\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2107\" data-start=\"2095\"\u003e950-0025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2179\" data-start=\"2108\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2137\" data-start=\"2108\"\u003e\u003cstrong data-end=\"2136\" data-start=\"2110\"\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2179\" data-start=\"2137\" data-col-size=\"sm\"\u003e120 × 135 × 44 mm (4.7 × 5.4 × 1.7 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2212\" data-start=\"2180\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2193\" data-start=\"2180\"\u003e\u003cstrong data-end=\"2192\" data-start=\"2182\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2212\" data-start=\"2193\" data-col-size=\"sm\"\u003e0.3 kg (0.7 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2255\" data-start=\"2213\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2229\" data-start=\"2213\"\u003e\u003cstrong data-end=\"2228\" data-start=\"2215\"\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2255\" data-start=\"2229\" data-col-size=\"sm\"\u003eIP20 (Indoor Use Only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2317\" data-start=\"2256\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2284\" data-start=\"2256\"\u003e\u003cstrong data-end=\"2283\" data-start=\"2258\"\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2317\" data-start=\"2284\" data-col-size=\"sm\"\u003e-20°C to 50°C (-4°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2378\" data-start=\"2318\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2344\" data-start=\"2318\"\u003e\u003cstrong data-end=\"2343\" data-start=\"2320\"\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2378\" data-start=\"2344\" data-col-size=\"sm\"\u003e-40°C to 85°C (-40°F to 185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2428\" data-start=\"2379\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2404\" data-start=\"2379\"\u003e\u003cstrong data-end=\"2403\" data-start=\"2381\"\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2428\" data-start=\"2404\" data-col-size=\"sm\"\u003e\u0026lt;95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2476\" data-start=\"2429\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2452\" data-start=\"2429\"\u003e\u003cstrong data-end=\"2451\" data-start=\"2431\"\u003eStorage Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2476\" data-start=\"2452\" data-col-size=\"sm\"\u003e\u0026lt;95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2526\" data-start=\"2477\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2492\" data-start=\"2477\"\u003e\u003cstrong data-end=\"2491\" data-start=\"2479\"\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2526\" data-start=\"2492\"\u003eBuilt-in Surface Mount Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2547\" data-start=\"2527\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2541\" data-start=\"2527\"\u003e\u003cstrong data-end=\"2540\" data-start=\"2529\"\u003eMarking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2547\" data-start=\"2541\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2552\" data-start=\"2549\"\u003e\n\u003ch2 data-end=\"2583\" data-start=\"2554\"\u003eVideo\u003c\/h2\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/fwuDmoGVIIk?si=K_emxmCT-jp3vkvv\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003chr data-end=\"2552\" data-start=\"2549\"\u003e\n\u003ch2 data-end=\"2583\" data-start=\"2554\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the LYNK II required for Discover batteries?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is required when closed-loop communication with supported inverters is desired. It ensures optimized battery charging and system control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this be used outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The LYNK II is rated IP20 and is intended for indoor installation only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it work with all inverters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt works with compatible hybrid inverter brands that support Discover battery communication protocols.\u003c\/p\u003e\n\u003chr data-end=\"3031\" data-start=\"3028\"\u003e\n\u003ch2 data-end=\"3042\" data-start=\"3033\"\u003eManual\u003c\/h2\u003e\n\u003cul data-end=\"3176\" data-start=\"3044\"\u003e\n\u003cli data-end=\"3176\" data-start=\"3044\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/6707\/8952\/files\/Discover_Energy_Lynk_II_Communication_Gateway.pdf?v=1771431956\" target=\"_blank\"\u003eDiscover Energy Lynk II Communication Gateway Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-end=\"3176\" data-start=\"3044\"\u003e\n\u003cp data-end=\"3176\" data-start=\"3046\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/6707\/8952\/files\/Discover_Energy_Lynk_II_Communication_Gateway_Spec_Sheet.pdf?v=1771432006\" rel=\"noopener\" target=\"_blank\"\u003eDiscover Energy Lynk II Communication Gateway Spec Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/www.solar-electric.com\/lib\/wind-sun\/Discover-opm-lynk-2-manual.pdf\" class=\"decorated-link\" rel=\"noopener\" data-end=\"3176\" data-start=\"3046\"\u003e\u003cspan class=\"ms-0.5 inline-block align-middle leading-none\" aria-hidden=\"true\"\u003e\u003csvg class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\" data-rtl-flip=\"\" aria-hidden=\"true\" height=\"20\" width=\"20\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-gvfid0kn.svg#304883\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Discover Energy","offers":[{"title":"Default Title","offer_id":51439853601064,"sku":"950-0025","price":462.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/6707\/8952\/files\/Discover_Energy_Lynk_II_Communication_Gateway.png?v=1771430110","url":"https:\/\/offgridsource.com\/products\/discover-energy-lynk-ii-communication-gateway","provider":"Off-Grid Source","version":"1.0","type":"link"}