Request a Free Solar ProposalAt this scale the question stops being whether it will run your house and becomes what your utility thinks about it. Two hybrid inverters, 16,200W of bifacial solar, and 51.2kWh of storage in two cabinets, giving 20,000W of continuous split-phase output. It produces 65 to 81kWh on a good day, three to four times what an average American home uses, and a refrigerator runs 291 hours on the battery alone with nothing coming off the roof.
At 16.2kW, some utilities will say no. Residential interconnection limits vary by territory, but a system this size sits past the threshold where many require a supplemental impact study, impose an export cap, or push you onto a commercial service. That is a conversation to have with your utility before you buy, not after the pallets arrive. The inverters carry UL1741, CSA C22.2 and UL1699B, which settles the equipment question, but the size question is local and it is what most often stops a project this large. If the answer comes back no, this kit runs fully off-grid and skips the paperwork entirely.

Three common load profiles, with how long the battery alone carries each one with no sun and no grid. On a system this size the battery is the outage plan rather than the daily plan: in normal operation the array covers all three several times over and the bank barely moves.
| Setup | Continuous draw | Runs for |
| Essential. Refrigerator, LED lighting, Starlink or router, phone and laptop charging, a TV. | ~500W | ~87 hours |
| Household. All of the above plus a chest freezer, ceiling fans, a home office, a well pump cycling, microwave and power tool bursts. | ~1,500W | ~29 hours |
| Heavy. All of the above plus central AC or shop equipment running continuously. | ~3,500W | ~12 hours |
The 16.2kW array produces roughly 65 to 81kWh per day at 4 to 5 peak sun hours, and more where the panels pick up reflected light from the back. That is comfortably beyond what almost any single property consumes, which is the point of a hybrid at this scale: the array runs the building, fills 51.2kWh of storage, and the surplus offsets or exports rather than being wasted.
Estimated runtimes below are from a full battery with no solar and no grid, based on 43.7kWh delivered to AC loads after battery and inverter losses. Real numbers depend on your specific appliances and how many run at once.
| Load | Draw | Runtime on battery alone |
| Chest freezer | ~100W avg | ~437 hours |
| Refrigerator | ~150W avg | ~291 hours |
| Cabin essentials | ~250W avg | ~174 hours |
| Lights, electronics, internet | ~300W | ~145 hours |
| Full household (essentials only) | ~800W avg | ~54 hours |
| Window AC unit | ~900W | ~48 hours |
| Microwave | 1,000W | ~43 hours cumulative |
| Power tools (intermittent) | ~1,200W | ~36 hours |
| Well pump (1HP) | ~1,200W running | ~36 hours |
| Central AC (2-ton) | ~3,000W | ~14 hours |
| Electric water heater | ~4,500W | ~9 hours |
Two things are worth saying plainly about a system this large. The good one: ten batteries in parallel supply well beyond what two inverters can draw from a 48V bus, so the 20,000W rating is the real ceiling rather than the battery, which is not true of every kit at the top of a range. The honest one: this is still a hybrid, and hybrids trade surge for grid capability. Our off-grid inverters are rated to roughly double their continuous output for twenty seconds. This pair tops out at 22,800VA, close to its continuous rating. For household and light commercial loads that is fine. For a deep submersible pump or a large compressor, tell us what it is before you order and we will check it against the numbers.

It works with the grid, not just instead of it - Grid-tied, off-grid and backup operation from two paralleled units, with selectable priority modes so you decide whether solar, battery or utility gets used first. That is the whole reason to buy a hybrid rather than an off-grid inverter.
20,000W continuous, up to 22,800W - Each inverter is rated 10,000W with an 11,400W maximum at unity power factor, which is where the 11.4kW name comes from. Two of them paralleled gives the honest pair of numbers above. Worth knowing so you size against the real figure rather than the badge.
Ten batteries mean the inverters are the ceiling - 51.2kWh across ten SG48100P units supplies far more current than two inverters can draw from a 48V bus. On several kits at the top of a range the battery quietly caps output below the inverter rating. Not this one.
16,200W of bifacial N-type solar - Thirty-six dual-glass modules that generate from the rear face as well as the front, at up to 80% of front-side output over a reflective surface. N-type cells avoid the light-induced degradation of conventional P-type panels and carry a 30 year linear performance warranty.
Six MPPT inputs, four of them used - Three per inverter. The kit ships four PV breakers and four cable sets for a four-string array, which leaves two tracker inputs completely free for expansion later without new hardware.
Wide MPPT window, 70V to 540V - Far wider than our off-grid inverters, which start tracking at 125V or 150V. On a 36 panel array split across roof planes that flexibility is the difference between a clean design and a compromise.
Two enclosed cabinets and 420A of combined charging - Both cabinets ship with the kit rather than being sourced separately, and the pair recharges fast enough to refill 51.2kWh inside a single good day.

Every major system component including both battery cabinets, matched and ready to wire together.
Financing is available through Affirm. Select Affirm at checkout to see monthly payment options before you place the order.
How it ships. Kits ship freight on multiple pallets, which runs longer than the parcel deliveries in our shipping policy: typically 5 to 10 business days. Liftgate and pallet jack are included at no charge, so the driver gets everything off the truck and onto the ground at your address. Thirty-six panels, ten batteries and two cabinets is the heaviest shipment we send. Plan the route from the driveway to the equipment room in advance and have equipment, not just people. We send tracking as soon as it leaves the warehouse, and the freight carrier will contact you directly to schedule a delivery window. Someone needs to be there to receive it. Inspect every pallet before you sign. Damaged in transit? We cover it.
Installation, if you're connecting to the grid. Start with your utility, not with us. At 16.2kW you are likely past the fast-track threshold in many territories, which can mean a supplemental impact study, an export limit, additional protective equipment, or a move to a commercial tariff. Any of those changes the economics, and all of them take time. Interconnection also needs a building permit, a licensed electrician and an inspection. The inverters' UL1741, CSA C22.2 and UL1699B listings are what make them eligible and are usually the first thing both the utility and the inspector ask for, but the application is yours to file.
Installation, if you're running it off-grid. Without a utility connection there is no interconnection agreement and permitting is often much simpler. Requirements still vary by location, particularly for a ground mount of this size, so check with your local building department. Wiring two paralleled hybrids and a ten-battery bank is professional work regardless of your own experience.
Wire the panels as four strings of nine, two to each inverter. That is what the four PV breakers and four sets of extension cable are for. Nine of these panels in series operate near 271V and reach 315V open circuit, sitting comfortably inside the 70 to 540VDC window and well under the 600V ceiling even on a cold morning, and each string draws 16A against a 22A tracker limit. Each inverter then carries 8,100W against a 15,000W limit, and two of its three MPPT inputs, which leaves genuine room to add panels later without buying anything else.
The two inverters must be commissioned as a parallel pair. They ship configured for it, but the communication cabling and the firmware settings on both units have to match before the system is energised. Done properly they behave as one 20,000W inverter. Done improperly they work against each other. This is routine for a solar installer and it is one of several reasons we treat this kit as a professional installation.
Three hybrids on the same inverter platform. Each step up adds array and storage, and each step up makes the utility conversation harder. That trade is the real decision here.
| Kit | What changes | Take this if |
| SGH-11N2E. 11.4kW hybrid, 7.2kW solar, 20.48kWh | One inverter, 16 panels, four batteries. Less than half the array and 40% of the storage, and an interconnection application most utilities approve without a second look. | A suburban or rural home with a real power bill, where 7.2kW covers consumption and you want the paperwork to be straightforward. |
| SGH-11N3E. 11.4kW hybrid, 12.6kW solar, 30.72kWh | Still one inverter, with 28 panels and six batteries. Roughly three quarters of this array and 60% of the storage, at 10,000W of output instead of 20,000W. | A large house or small business where one inverter is enough and 12.6kW clears your utility's review. |
| This kit. 22.8kW hybrid, 16.2kW solar, 51.2kWh | Two paralleled inverters, 36 panels, ten batteries and two cabinets. Double the output of either kit above, and the hardest interconnection of the three to get approved. | Small commercial, or a large property where the bill justifies the array and you have already checked what your utility allows. |
Do not buy this one from a web page. Our sales engineers will size it against your actual bill and load profile, tell you honestly whether 16.2kW is likely to clear your utility's review and what to do if it will not, plan the four-string layout across your roof planes or ground mount, check any hard-starting equipment against the inverters' real surge capability, and list the site-specific parts your install needs. On a system this size that conversation routinely changes the specification, usually in your favour. Call 877-556-3347.
Warranty claims are handled through Off-Grid Source. Send us photos and order details, and we take it from there.
| Component | Coverage |
| Hybrid inverters | 10 years |
| Batteries | 10 years |
| Solar panels | 30 year linear performance, 12 year product |
| Specification | Details |
| Rated Continuous Output | 20,000W (2 X 10,000W in parallel) |
| Maximum Output | 22,800W at PF=1 (22,800VA apparent) |
| AC Output | 120/240V split phase, or 208V two or three phase |
| Operating Mode | Grid-tied, off-grid, and backup |
| DC Voltage | 48V |
| Max Solar Input | 30,000W across six MPPT inputs (15,000W per inverter) |
| Total Watt of Panels | 16,200W |
| Per Panel Watt | 450 Watt bifacial N-type |
| Panel NO. | 36 pcs |
| Total KWH of Batteries | 51.2KWH |
| Usable Energy Delivered to AC Loads | approx. 43.7KWH |
| Chemistry | LiFePO4 Lithium |
| Battery NO. | 10 pcs, two enclosed cabinets included |
| Battery Spec | 48V 100AH SG48100P |
| Specification | Details |
| Rated AC Output Per Unit | 10,000W |
| Maximum AC Output Per Unit | 11,400W at PF=1 (11,400VA apparent) |
| Combined Output | 20,000W rated, 22,800W maximum |
| Output Waveform | Pure Sine Wave |
| AC Output | 120/240V (split phase) or 208V (two or three phase) |
| MPPT Operating Voltage Range | 70 to 540VDC |
| PV Startup Voltage | 70VDC |
| Max PV Input Voltage | 600VDC |
| Max PV Input Power | 15,000W per inverter |
| Nos. of MPPT | 3 per inverter, 6 total |
| Max Input Current per MPPT | 30A / 22A / 22A |
| Max Charging Current | 210A per inverter, 420A combined |
| Dimension | 16.5 X 31.5 X 9.4 inch |
| Weight | 88 lbs each |
| Certificates | UL1741, CSA C22.2, UL1699B |
| Warranty | 10 Years |
| Specification | Details |
| Nominal Voltage | 51.2V |
| Nominal Capacity | 100AH |
| Energy Per Unit | 5.12KWH |
| Bank Total | 51.2KWH |
| MAX Continuous Charge Current | 100A |
| Charge Cut-off Current | 5A |
| Discharge Cut-off Voltage | 43.2V |
| Cycle Life | 7,000+ cycles |
| Communication Protocol | RS232 / RS485 / CAN |
| Storage Temperature | 14°F to 113°F |
| Dimension | 19.3 X 18.9 X 5.5 inch |
| Weight | 93 lbs each |
| Certificates | UL1973, UN38.3, CE |
| Warranty | 10 Years |
| Specification | Details |
| Peak Power | 450W |
| Cell Type | N-type Monocrystalline, bifacial |
| Product Tolerance | ±3% |
| Maximum Power Current (IMP) | 14.97A |
| Maximum Power Voltage (VMP) | 30.08V |
| Short Circuit Current (ISC) | 16.05A |
| Open Circuit Voltage (VOC) | 35.03V |
| Connectors | MC4 compatible |
| Product Dimension | 69.4 X 44.7 X 1.4 inch |
| Product Weight | 53.4 lbs |
| Material and Workmanship Warranty | 12 Years |
| Performance Warranty | 30 Years linear |
| Certificates | UL61730, TUV, IEC, CEC, CE |
Will my utility approve a 16.2kW array?
This is the question to answer first, and the honest answer is that it depends on your territory and often on your service size. Many utilities fast-track residential systems up to around 10kW and apply a supplemental review above it. Some cap export at your historical consumption. Some require additional protective equipment or move you to a commercial tariff. The inverters' UL1741 and UL1699B listings settle the equipment half of the question. The size half is local. Call your utility before you order, not after, and if the answer is unfavourable the same kit runs fully off-grid.
Does this kit include everything I need to install it?
Every major component, including both enclosed battery cabinets, which on most systems at this scale are separate purchases: both hybrid inverters, all ten batteries, all thirty-six panels, four PV breakers, four sets of solar extension cable, both DC breakers and the battery cabling. What varies is the building side, and at this size that side is a project in itself: ground-mount structure or racking across multiple roof planes, conduit, junction boxes, building wire, a critical loads panel, and labor. If you are interconnecting, add the utility application, any protective equipment they specify, and the electrician's time.
Can ten batteries really keep up with two inverters?
Comfortably, and this is worth knowing because it is not true of every kit at the top of a range. Two inverters at full output draw roughly 425A from a 48V bus, spread across ten batteries. That is about 43A each, well inside what these cells sustain. The inverters are the ceiling here, not the bank.
How should the panels be wired?
Four strings of nine, two to each inverter. Nine in series operate near 271V and reach 315V open circuit, comfortably inside the 70 to 540V window and far below the 600V ceiling even in cold weather, at 16A per string against a 22A limit. That uses two of the three MPPT inputs on each inverter, so two remain free if you add panels later.
What does running two hybrids in parallel involve?
They ship configured as a pair and are joined by a communication cable that keeps them synchronised and sharing load. Both need matching firmware settings before the system is energised. Done properly they behave as one 20,000W inverter. Done improperly they work against each other. Routine for a solar installer, and one of the reasons this is not a DIY kit.
How much energy will this generate daily?
The 16.2kW array produces roughly 65 to 81kWh per day at 4 to 5 peak sun hours, plus whatever the rear faces add. For almost any single property that is well above consumption, which is the intent on a hybrid: the surplus offsets or exports rather than sitting idle.
Do I have to connect it to the grid?
No. The same kit runs fully off-grid, and at 16.2kW of array with 51.2kWh of storage it does that very well. You lose the ability to draw from the utility on a bad week and you lose any export credit, but you skip the interconnection process entirely. For some customers that trade is worth making on its own.
Can I install this myself?
We would not recommend it. Thirty-six panels, two 88 lb inverters that must be commissioned as a pair, and two battery cabinets weighing around 1,000 lbs loaded is a professional installation. If you are interconnecting, most utilities require a licensed electrician regardless of your own experience.
Is LiFePO4 safe?
It's the safest widely available lithium chemistry, with strong thermal stability, long service life and minimal maintenance. These cells carry UL1973 and UN38.3, and every battery includes BMS protection against overcharge, deep discharge, overheating, overload and short circuit.
Shipping is free across the Lower 48. No fuel surcharges, no residential fees, and no liftgate charge on freight orders. The price you see is the price you pay. Read our full Shipping Policy here.
Most orders leave the warehouse in 1 to 2 business days and arrive within 3 to 10 business days. We send tracking the moment it ships.
Anything that ships on a pallet goes freight with liftgate and pallet jack included, so the driver gets it off the truck and onto the ground at your address. The carrier will call you directly to schedule a delivery window.
Returns are 30 days from delivery. For freight deliveries, inspect the shipment before you sign for it. If something is damaged in transit, note it on the delivery receipt and we handle the freight claim, not you. Read more about our Returns Policy here.
Buying solar online should not mean guessing your way through the install. Here’s what you get with Off-Grid Source.
You May Also Like
Trusted By 10,000+ Customers. See All Reviews.
I was a DIY solar power wannabe... that is 'til I connected with Manny... The man's a prince! He not only knows his stuff; he walked me through all things electrical. To make sure I had all I needed... he gave me his cell phone # to text him anytime I got confused... nights and weekends included. The prices were very competitive... definitely go with Manny -- you won't go wrong!
Bruce D.
I am always hesitant to buy things at places I have never shopped... I want to give a shout out to Manny who with great patience and knowledge helped me get my orders... I felt valued as a customer and I will definitely be back in the future. I highly recommend them, they make you feel like family.
Jennene A.
I'm about to go off grid. I called Manny, he walked me through everything so I could truly understand what I needed and never tried to upsell me. He was honest and made a customer for life.
Ray B.
I would personally like to thank Manny... I purchased the inverter and decided I needed to return it... Manny was very understanding and went out of his way to help me return the product and not even have to pay for shipping return. He gives this company reputation, honor and quality customer service!
Roger V.
I have been talking with Manny the owner... He has not only helped me design a system but he's been assisting with the install and components. I am super pleased so far with the assistance.
Jeff S.
We added 2 more batteries to our current set up. Pleased with the customer service from Off-Grid Source! Will be back!
Jason
Very fast response times. Very professional. I highly recommend!
Ray W.
Get Off-Grid Tips, Deals & System Guides, Straight to Your Inbox. Plus, Unlock a Mystery Discount On Your First Order.
Sign up for emails and get exclusive offers, new product drops, and expert advice to help you build the right solar setup with confidence.
Added to your cart:
placeholder