SunGold Power 18kW Off-Grid Solar Kit, 9kW Solar, 30.72kWh Battery | 120/240V | SGR-18K20E
Estimated Delivery Between
and .
Order within to get it by the earliest date.
Free Shipping In The USA | Call Us: 877-556-3347
Free Shipping In The USA | Call Us: 877-556-3347
Found A Better Price?
Share it with us now and we will beat it. Get the best deal online, guaranteed!
Estimated Delivery Between
and .
Order within to get it by the earliest date.
Not Sure This Is The Right System?
Request a Free Solar ProposalMost systems are sized by what they can run. This one is sized by what it can start. The low-frequency transformer inverter is rated for 54,000W for twenty seconds, three times its 18,000W continuous output and the highest surge rating in the LFPV family. That is the headroom a deep submersible pump and a shop compressor need when they come on together and a normal inverter gives up. Behind it sit 9,000W of bifacial solar and 30.72kWh of storage. A refrigerator runs 162 hours on the battery alone, and a good day of sun makes 36 to 45kWh.
Low frequency buys surge and costs efficiency. The transformer that delivers 54,000W also weighs 177 lbs, converts at a peak 88% against the 92% of our high-frequency inverters, and draws up to 25W sitting idle, which is roughly 0.6kWh a day doing nothing. Every runtime figure on this page already accounts for that. If nothing on your property starts hard, a high-frequency kit gets more usable energy from the same battery. If something does, this is the class of inverter that handles it.

Three common load profiles, with how long this kit carries each one from a full battery and no sun. These are steady-state figures. On a normal day the 9kW array covers all three outright and the battery only does overnight work.
| Setup | Continuous draw | Runs for |
| Essential. Refrigerator, LED lighting, Starlink or router, phone and laptop charging, a TV. | ~500W | ~48 hours |
| Household. All of the above plus a chest freezer, ceiling fans, a home office, a well pump cycling, microwave and power tool bursts. | ~1,500W | ~16 hours |
| Heavy. All of the above plus central AC or shop equipment running continuously. | ~3,500W | ~6 hours |
The 9kW array produces roughly 36 to 45kWh per day at 4 to 5 peak sun hours, and more where the rear face of the panels picks up reflected light. That is well above what the 30.72kWh bank holds, so a normal day refills the battery by early afternoon and runs the property off the panels for the rest of it.
Estimated runtimes below are from a full charge with no solar input, based on 24.3kWh delivered to AC loads. That is the 30.72kWh bank less the 10% the battery management system holds back, then less this inverter's 88% conversion efficiency. Real numbers depend on your specific appliances and how many run at once.
| Load | Draw | Runtime on battery alone |
| Chest freezer | ~100W avg | ~243 hours |
| Refrigerator | ~150W avg | ~162 hours |
| Cabin essentials | ~250W avg | ~97 hours |
| Lights, electronics, internet | ~300W | ~81 hours |
| Full household (essentials only) | ~800W avg | ~30 hours |
| Window AC unit | ~900W | ~27 hours |
| Microwave | 1,000W | ~24 hours cumulative |
| Power tools (intermittent) | ~1,200W | ~20 hours |
| Well pump (1HP) | ~1,200W running | ~20 hours |
| Central AC (2-ton) | ~3,000W | ~8 hours |
| Electric water heater | ~4,500W | ~5 hours |
The table shows duration. The inverter is about the other axis. A 1HP well pump draws 1,200W running and can pull five to seven times that in the first second, and a 2-ton AC compressor behaves the same way. What separates this kit from a high-frequency system with a similar continuous rating is that both can start at once, on top of a house that is already loaded, without anything tripping. Where this kit asks for honesty is the other direction. An electric water heater, central AC and a well pump running together come to about 8,700W, less than half of what the inverter will give, so 18,000W is rarely the thing that stops you. The battery is. At full output this bank lasts about eighty minutes. Buy this kit for what it starts, not for how long it holds 18,000W.

54,000W of surge for 20 seconds - Three times continuous output, against the two times a high-frequency inverter gives. A real transformer is doing that work, and it is the reason to choose this kit over a larger number on a lighter unit.
18,000W continuous, 120/240V split phase - Enough to run a house and a workshop at the same time, with the 240V equipment fed directly rather than through a separate transformer.
9,000W of bifacial N-type solar - Twenty dual-glass modules producing 36 to 45kWh a day, comfortably more than the battery holds, so the bank refills and the property runs off the panels while it does.
CoreX 5 Pro batteries, 100A continuous discharge each - Six units, 30.72kWh, and SunGold publishes the discharge figure rather than only the charge figure. Six in parallel supply well beyond what a 18,000W inverter draws, so the inverter is the honest ceiling.
Two 100A MPPT controllers with Bluetooth - Solar is handled outside the inverter on this platform. You can see and tune each string from your phone, and a controller fault does not take the inverter down with it.
95A AC charger and generator input - Accepts a generator from 140V to 270V and puts roughly 4.9kW back into the bank. Worth knowing that this is a smaller charger than the 15kW model in the same family carries, so if fast generator recharging matters more to you than starting current, compare the two before deciding.
10ms transfer time - Fast enough that computers, routers and modern appliances never register the switch between sources.

Every major system component, matched and ready to wire together.
Financing is available through Affirm. Select Affirm at checkout to see monthly payment options before you place the order.
How it ships. Kits ship freight on a pallet, which runs longer than the parcel deliveries in our shipping policy: typically 5 to 10 business days. Liftgate and pallet jack are included at no charge, so the driver gets it off the truck and onto the ground at your address. The inverter is 197 lbs on its own and the six batteries are 569 lbs between them, on top of twenty panels. This is not a two-person unload. Work out how it gets from the driveway to where it is going before delivery day and line up real help. We send tracking as soon as it leaves the warehouse, and the freight carrier will contact you directly to schedule a delivery window. Someone needs to be there to receive it. Inspect the shipment before you sign. Damaged in transit? We cover it.
Installation. Because this is an off-grid system with no utility interconnection, permitting is often simpler than grid-tied solar. Requirements still vary by location, especially for roof-mounted arrays or permanent electrical work, so check with your local building department before installing. At 18,000W, tying into an existing house panel is work for a licensed electrician.
Wire the panels as two strings of ten, one to each charge controller, each string arranged as five in series and two of those in parallel. Five of these panels in series operate near 150V and reach 175V open circuit, which stays well under the controller's 250V ceiling even on a cold morning when panel voltage rises. Two such strings in parallel draw 32A against a 70A limit, and put 4,500W into a controller rated for 5,280W at 48V. Do not run ten in series into one controller: that exceeds the voltage ceiling outright.
The battery bank needs a busbar, not a daisy chain. This is the detail most often missed at this system size. An 18,000W inverter pulls roughly 400A from a 48V bank, and the CoreX manual limits a standard parallel battery connection to 100A total. Six batteries feeding this inverter must land on a properly rated busbar so the current is shared evenly and no single battery cable carries the whole load. Our sales engineers will spec it with your order. It is a cheap part and it is not optional.
These batteries stop charging at 39°F, not at freezing. The CoreX 5 Pro charge window is 39.2°F to 131°F, slightly narrower than the standard lithium cells in our other kits. They discharge down to -4°F, so a cold snap never leaves you without power, but the array will not put energy back in until the battery space warms. If your battery room is unheated, tell us before you order.
Three low-frequency kits on the same platform. This is the top of the family, and the honest thing to notice is that it carries exactly the same array and the same battery as the kit below it.
| Kit | What changes | Take this if |
| SGR-12K20E. 12kW, 36,000W surge, 5.4kW solar, 25.6kWh | A step down in every dimension: 6,000W less output, 18,000W less surge, 40% less array and a fifth less storage. | One hard-starting load rather than several, on a property with modest daily consumption. |
| SGR-15K20E. 15kW, 45,000W surge, 9kW solar, 30.72kWh | Identical array, identical battery, identical runtime. 3,000W less output, 9,000W less surge, and a larger 135A AC charger for generator recharging. | The same properties, unless you have equipment that specifically needs the extra starting current. |
| This kit. 18kW, 54,000W surge, 9kW solar, 30.72kWh | The most output and the most surge of the three low-frequency kits. 54,000W for twenty seconds will start almost anything a property can throw at it. | Deep submersible pumps, large compressors, or several heavy motors that come on together. |
Tell us the exact equipment you need to start: pump horsepower and depth, compressor size, whether anything is three phase. That is the question this kit exists to answer and it is worth checking rather than assuming. We will also spec the battery busbar described above, size the array against your actual consumption, and list the site-specific parts your install needs, including racking for twenty panels and the tie-in to your existing panel. Call 877-556-3347.
Warranty claims are handled through Off-Grid Source. Send us photos and order details, and we take it from there.
| Component | Coverage |
| Inverter | 3 years |
| Batteries | 10 years |
| MPPT charge controllers | 3 years |
| Solar panels | 30 year linear performance, 12 year product |
| Specification | Details |
| Max Continuous Output | 18,000W |
| Surge Output | 54,000W for 20 seconds |
| AC Output | 120V / 240V split phase |
| Inverter Type | Low frequency, transformer based |
| DC Voltage | 48V |
| Solar Charging | 2 X external 100A MPPT controllers |
| Total Watt of Panels | 9000W |
| Per Panel Watt | 450 Watt bifacial N-type |
| Panel NO. | 20 pcs |
| Total KWH of Batteries | 30.72KWH |
| Usable Energy Delivered to AC Loads | approx. 24.3KWH |
| Chemistry | LiFePO4 Lithium |
| Battery NO. | 6 pcs, brackets included |
| Battery Spec | 51.2V 100AH CoreX 5 Pro |
| Specification | Details |
| Continuous Output | 18,000W |
| Surge Rating | 54,000W for 20 seconds |
| Output Waveform | Pure Sine Wave, or same as input in bypass mode |
| AC Output | 120V / 240V split phase |
| AC Input Range | 164 to 243VAC utility, 140 to 270VAC generator |
| Transfer Time | 10ms typical |
| Type | Low frequency, transformer based |
| Peak Efficiency | >88% |
| Idle Consumption | <25W with power saver enabled |
| AC Charger Current | 95A ±5A |
| Solar Input | None built in, external charge controllers included |
| Generator Support | Yes |
| Dimension | 28.7 X 16.5 X 8.7 inch |
| Weight | 197 lbs |
| Warranty | 3 Years |
| Specification | Details |
| Nominal Voltage | 51.2V |
| Nominal Capacity | 100AH |
| Energy Per Unit | 5.12KWH |
| Bank Total | 30.72KWH |
| Voltage Range | 43.2V to 56.8V |
| Standard Charge / Discharge Current | 50A |
| MAX Continuous Charge Current | 95A |
| MAX Continuous Discharge Current | 100A per unit |
| Charging Temperature | 39.2°F to 131°F |
| Discharging Temperature | -4°F to 131°F |
| Recommended Operating Range | 50°F to 113°F |
| Communication Protocol | RS485 / CAN |
| Parallel Capability | Up to 15 units, busbar required above 100A total |
| Ingress Protection | IP20, indoor installation |
| Dimension | 20.1 X 17.4 X 5.1 inch |
| Weight | 94.8 lbs each |
| Warranty | 10 Years |
| Specification | Details |
| System Voltage | 12V / 24V / 36V / 48V auto detect |
| Maximum PV Open-Circuit Voltage | 250V |
| Maximum PV Short-Circuit Current | 70A |
| Rated Charging Current | 100A, settable 0 to 100A |
| Maximum Solar Input at 48V | 5,280W per controller |
| MPPT Tracking Efficiency | >99% |
| Monitoring | Bluetooth and mobile app |
| Dimension | 12.4 X 8.9 X 4.8 inch |
| Weight | 12.5 lbs each |
| Warranty | 3 Years |
| Specification | Details |
| Peak Power | 450W |
| Cell Type | N-type Monocrystalline, bifacial |
| Product Tolerance | ±3% |
| Maximum Power Current (IMP) | 14.97A |
| Maximum Power Voltage (VMP) | 30.08V |
| Short Circuit Current (ISC) | 16.05A |
| Open Circuit Voltage (VOC) | 35.03V |
| Connectors | MC4 compatible |
| Product Dimension | 69.4 X 44.7 X 1.4 inch |
| Product Weight | 53.4 lbs |
| Material and Workmanship Warranty | 12 Years |
| Performance Warranty | 30 Years linear |
| Certificates | UL61730, CEC Listed |
What does low frequency actually mean, and why would I want it?
It describes how the inverter builds its AC output. A low-frequency inverter uses a heavy iron transformer, which is why this unit weighs 197 lbs where a comparable high-frequency inverter weighs about 54 lbs. The transformer lets it deliver enormous current for a moment without folding, which is exactly what a motor demands at startup. The trade is weight, cost, a peak efficiency of 88% against 92%, and up to 25W of idle draw. If you have hard-starting equipment those trades are worth making. If you do not, they are not.
Does this kit include everything I need to install it?
The system side, yes: the inverter, all six batteries with brackets, both charge controllers, all twenty panels, the 400A DC breaker, both PV breakers, two sets of solar extension cable, the battery-to-controller cabling, the 4/0 AWG battery cable and the Z-brackets. Two things to add. First, a properly rated DC busbar for the battery bank, described above, which we spec with your order. Second, the building side: rail racking for twenty panels, conduit, junction boxes, building wire, a critical loads panel or transfer switch, generator input wiring and labor. Those depend on your structure and local code, which is why we spec them per site.
Why does the battery bank need a busbar?
Because a 18,000W inverter draws about 400A from a 48V bank, and the CoreX manual limits a standard parallel battery connection to 100A total. Without a busbar the first battery in the chain carries far more than its share. With one, all six share the load evenly and each stays inside its 100A rating. This is normal practice at this system size, it is a cheap part, and it needs planning rather than discovering.
How cold can the batteries get?
They discharge down to -4°F, so a cold night never leaves you without power. Charging is the narrower window at 39.2°F to 131°F, slightly tighter than the standard lithium in our other kits, which cut off at freezing. An unheated battery room in a real winter will discharge normally but refuse a charge until it warms. If that describes your install, call us first.
How should the panels be wired?
Two strings of ten, one to each controller, with each string built as five panels in series and two of those runs paralleled. Five in series operate near 150V and reach 175V open circuit, staying under the 250V ceiling even on a cold morning. Paralleled they draw 32A against a 70A limit and deliver 4,500W into a controller rated for 5,280W at 48V. Ten in series into one controller would exceed the voltage ceiling.
How much energy will this generate daily?
The 9kW array produces roughly 36 to 45kWh per day at 4 to 5 peak sun hours, plus whatever the rear faces add. That is more than the 30.72kWh bank holds, which is the intent: the battery refills and the property runs off the panels while it does.
Should I buy this or the 15kW version?
Ask what you need to start. The two kits carry the same twenty panels and the same six batteries, so they generate the same energy and run for exactly as long as each other. This one gives 3,000W more continuous output and 9,000W more surge. If you have a deep submersible pump or a large compressor that needs it, take this one. If you do not, the 15kW costs less, runs identically, and actually has the larger AC charger for generator recharging.
Can I install this myself?
Parts of it. Running PV, setting the controllers and wiring the DC side are within reach for someone with real electrical experience. Hanging a 197 lb inverter is a two-person job with proper fixings, tying into a house panel at 18,000W is work for a licensed electrician, and the battery busbar should be sized by someone who has done it before.
Is LiFePO4 safe?
It's the safest widely available lithium chemistry, with strong thermal stability, long service life and minimal maintenance. Every battery includes BMS protection against overcharge, deep discharge, overheating, overload and short circuit.
Shipping is free across the Lower 48. No fuel surcharges, no residential fees, and no liftgate charge on freight orders. The price you see is the price you pay. Read our full Shipping Policy here.
Most orders leave the warehouse in 1 to 2 business days and arrive within 3 to 10 business days. We send tracking the moment it ships.
Anything that ships on a pallet goes freight with liftgate and pallet jack included, so the driver gets it off the truck and onto the ground at your address. The carrier will call you directly to schedule a delivery window.
Returns are 30 days from delivery. For freight deliveries, inspect the shipment before you sign for it. If something is damaged in transit, note it on the delivery receipt and we handle the freight claim, not you. Read more about our Returns Policy here.
Buying solar online should not mean guessing your way through the install. Here’s what you get with Off-Grid Source.
You May Also Like
Trusted By 10,000+ Customers. See All Reviews.
I was a DIY solar power wannabe... that is 'til I connected with Manny... The man's a prince! He not only knows his stuff; he walked me through all things electrical. To make sure I had all I needed... he gave me his cell phone # to text him anytime I got confused... nights and weekends included. The prices were very competitive... definitely go with Manny -- you won't go wrong!
Bruce D.
I am always hesitant to buy things at places I have never shopped... I want to give a shout out to Manny who with great patience and knowledge helped me get my orders... I felt valued as a customer and I will definitely be back in the future. I highly recommend them, they make you feel like family.
Jennene A.
I'm about to go off grid. I called Manny, he walked me through everything so I could truly understand what I needed and never tried to upsell me. He was honest and made a customer for life.
Ray B.
I would personally like to thank Manny... I purchased the inverter and decided I needed to return it... Manny was very understanding and went out of his way to help me return the product and not even have to pay for shipping return. He gives this company reputation, honor and quality customer service!
Roger V.
I have been talking with Manny the owner... He has not only helped me design a system but he's been assisting with the install and components. I am super pleased so far with the assistance.
Jeff S.
We added 2 more batteries to our current set up. Pleased with the customer service from Off-Grid Source! Will be back!
Jason
Very fast response times. Very professional. I highly recommend!
Ray W.
Get Off-Grid Tips, Deals & System Guides, Straight to Your Inbox. Plus, Unlock a Mystery Discount On Your First Order.
Sign up for emails and get exclusive offers, new product drops, and expert advice to help you build the right solar setup with confidence.
Added to your cart:
placeholder